ISO/Factory calibration
MP-100.09Z

ISO/Factory calibration
MP-100.09Z

according to ISO 9001

ISO/Factory calibration for MP-F22.20 spring hammer with impact energy of 2 J.

The scope of services includes the following:

  • Incoming inspection with visual and functional test
  • Cleaning of the test equipment from light contamination
  • Decision on the calibratability of the test equipment
  • Inspection of various wear parts
  • Calibration of the test equipment and optional adjustment
  • Documentation of the measured values in the factory calibration certificate
  • Marking by means of calibration test badge
  • Issue of a factory calibration certificate


Extended scope of services after separate order:

  • Replacement of wear parts such as the release lug, firing pin or springs.


  • Equipment

Impact-test Hammer
MP-F22.20

Special model with the impact energy of 2,00 Joule

Details